' // ActiveXperts Network Monitor  - VBScript based checks
' // For more information about ActiveXperts Network Monitor and VBScript, visit
' // http://www.activexperts.com/support/network-monitor/online/vbscript/
' ///////////////////////////////////////////////////////////////////////////////

Option Explicit

' Declaration of global variables
Dim   SYSDATA, SYSEXPLANATION   ' SYSDATA is displayed in the 'Data' column in the Manager; SYSEXPLANATION in the 'LastResponse' column

' Constants - return values
Const retvalUnknown = 1         ' ActiveXperts Network Monitor functions should always return True (-1, Success), False (0, Error) or retvalUnknown (1, Uncertain)

' // To test a function outside Network Monitor (e.g. using CSCRIPT from the
' // command line), remove the comment character (') in the following lines:
' Dim bResult
' bResult = CheckMountPointFreeSpace( "localhost", "", "C:\myMountPoint", 25000 )
' WScript.Echo "Return value: [" & bResult & "]"
' WScript.Echo "SYSDATA: [" & SYSDATA & "]"
' WScript.Echo "SYSEXPLANATION: [" & SYSEXPLANATION & "]"


Function CheckMountPointFreeSpace( strHost, strCredentials, strMountPoint, nRequiredSpaceMB )
' Description: 
'     This function checks if a Windows Mount Point has enough space left.
' Parameters:
'     1) strHost As String  - Hostname or IP address of the computer you want to monitor
'     2) strCredentials As String - Specify an empty string to use Network Monitor service credentials.
'         To use alternate credentials, enter a server that is defined in Server Credentials table.
'         (To define Server Credentials, choose Tools->Options->Server Credentials)
'     3) strMountPoint As String - The Mount point you want to check.
'     4) nRequiredSpaceMB As Int - The freespace required on the MountPoint
' Usage:
'     CheckMountPointFreeSpace( "<Hostname | IP>", "<Empty String | Server>", "<MountPoint>", <RequiredSpaceMB> )
' Sample:
'     CheckMountPointFreeSpace( "localhost", "",  "C:\myMountPoint", 25000)

  Dim strAltLogin, strAltPassword
  Dim objWMIService

  CheckMountPointFreeSpace = retvalUnknown  ' Default return value, and will be shown as a yellow (uncertain) icon in the Manager
  SYSDATA         = ""             ' SYSDATA displayed in the 'Data' column in the Manager          
  SYSEXPLANATION  = ""             ' SYSEXPLANATION displayed in the 'LastResponse' column in the Manager

  strAltLogin     = ""
  strAltPassword  = ""
  
  ' If alternate credentials are specified, retrieve the alternate login and password from the ActiveXperts global settings
  If( strAltCredentials <> "" ) Then	
    If( Not getCredentials( strHost, strAltCredentials, strAltLogin, strAltPassword, SYSEXPLANATION )) Then
      Exit Function
    End If
  End If  

  ' WMI Connect
  If( Not wmiConnect( strHost, strAltLogin, strAltPassword, objWMIService, SYSEXPLANATION ) ) Then
    Exit Function
  End If

  CheckMountPointFreeSpace =  checkMountPointFreeSpaceWMI( objWMIService, strHost, strMountPoint, nRequiredSpaceMB, SYSEXPLANATION, SYSDATA )
End Function


' //////////////////////////////////////////////////////////////////////////////
' // --- Private Functions section ---
' // Private functions names should start with a lower case character, so they 
' // will not be listed in the Network Monitor's function browser.
' //////////////////////////////////////////////////////////////////////////////

Function checkMountPointFreeSpaceWMI( objWMIService, strHost, strMountPoint, nRequiredSpaceMB, BYREF strSysExplanation, BYREF strSysData)
  Dim colDisks, objDisk	
  checkMountPointFreeSpaceWMI = retvalUnknown ' Default return value

On Error Resume Next
  Set colDisks = objWMIService.ExecQuery( "Select * FROM Win32_PerfFormattedData_PerfDisk_LogicalDisk")
  If( Err.Number <> 0 ) Then
    strSysData         = ""
    strSysExplanation  = "Unable to query WMI class on computer [" & strHost & "]" & Err.Number
    Exit Function
  End If
  If( colDisks.Count <= 0  ) Then
    strSysData         = ""
    strSysExplanation  = "No disks on computer [" & strHost & "]"
    Exit Function
  End If

On Error Goto 0

  For Each objDisk in colDisks
    If( Err.Number <> 0 ) Then
      checkMountPointFreeSpaceWMI    = False
      strSysExplanation              = "Unable to list disks on computer [" & strHost & "]"
      Exit Function
    End If

    If ( LCase(objDisk.Name) = LCase( strMountPoint ) ) Then
      ' Mount Point found
      If( nRequiredSpaceMB <= objDisk.FreeMegabytes ) Then
        checkMountPointFreeSpaceWMI = True                
      Else
        checkMountPointFreeSpaceWMI = False
      End If
        strSysData = objDisk.FreeMegabytes
        strSysExplanation = "MountPoint[" & strMountPoint & "] has " & objDisk.FreeMegabytes & "MB free space, " & nRequiredSpaceMB & "MB is required"
      Exit Function
    End If
  Next    

  strSysExplanation = "MountPoint[" & strMountPoint & "] was not found on[" & strHost & "]"
End Function

' //////////////////////////////////////////////////////////////////////////////

Function getCredentials( strHost, strAltCredentials, BYREF strAltLogin, BYREF strAltPassword, BYREF strSysExplanation )	

  Dim objNMServerCredentials
  
  strAltLogin = ""
  strAltPassword = ""
  strSysExplanation = ""
  
  getCredentials  = False    
  
  If( strAltCredentials = "" ) Then
    ' No alternate credentials specified, so login and password are empty and service credentials will be used
    getCredentials = True
    Exit Function
  End If
  
  Set objNMServerCredentials = CreateObject( "ActiveXperts.NMServerCredentials" )

  strAltLogin           = objNMServerCredentials.GetLogin( strAltCredentials )
  strAltPassword        = objNMServerCredentials.GetPassword( strAltCredentials )

  If( strAltLogin = "" ) Then
    getCredentials      = False
    strSysExplanation = "No alternate credentials defined for [" & strAltCredentials & "]. In the Manager application, select 'Options' from the 'Tools' menu and select the 'Server Credentials' tab to enter alternate credentials"
    Exit Function
  End If   

  getCredentials = True 

End Function

' //////////////////////////////////////////////////////////////////////////////

Function getCredentials( strHost, strAltCredentials, BYREF strAltLogin, BYREF strAltPassword, BYREF strSysExplanation )	

  Dim objNMServerCredentials
  
  strAltLogin = ""
  strAltPassword = ""
  strSysExplanation = ""
  
  getCredentials  = False    
  
  If( strAltCredentials = "" ) Then
    ' No alternate credentials specified, so login and password are empty and service credentials will be used
    getCredentials = True
    Exit Function
  End If
  
  Set objNMServerCredentials = CreateObject( "ActiveXperts.NMServerCredentials" )

  strAltLogin           = objNMServerCredentials.GetLogin( strAltCredentials )
  strAltPassword        = objNMServerCredentials.GetPassword( strAltCredentials )

  If( strAltLogin = "" ) Then
    getCredentials      = False
    strSysExplanation = "No alternate credentials defined for [" & strAltCredentials & "]. In the Manager application, select 'Options' from the 'Tools' menu and select the 'Server Credentials' tab to enter alternate credentials"
    Exit Function
  End If   

  getCredentials = True 

End Function

' //////////////////////////////////////////////////////////////////////////////

Function wmiConnect( strHost, strAltLogin, strAltPassword, BYREF objWMIService, BYREF strSysExplanation )	

  Dim objSWbemLocator, colItems
  Dim bConnectResult

  wmiConnect         = False
  Set objWMIService  = Nothing
      
  If( strAltLogin = "" ) Then	
    ' Connect to remote host on same domain using same security context
On Error Resume Next    
    Set objWMIService     = GetObject( "winmgmts:{impersonationLevel=Impersonate}!\\" & strHost &"\root\cimv2" )
    If( Err.Number <> 0 ) Then
      bConnectResult = False
    Else
      bConnectResult = True
    End If
On Error Goto 0    
    
  Else
    ' Connect to remote host using different security context and/or different domain 
On Error Resume Next        
    Set objSWbemLocator   = CreateObject( "WbemScripting.SWbemLocator" )
    Set objWMIService     = objSWbemLocator.ConnectServer( strHost, "root\cimv2", strAltLogin, strAltPassword )

    If( Err.Number <> 0 ) Then
      bConnectResult = False
    Else
      bConnectResult = True
    End If

    objWMIService.Security_.ImpersonationLevel = 3
On Error Goto 0    
    
  End If

  If( Not bConnectResult ) Then
    Set objWMIService  = Nothing
    wmiConnect         = False
    strSysExplanation  = "Unable to connect to [" & strHost & "]. Possible reasons: no WMI installed on the remote server, firewall blocking WMI calls, login failure, or remote server down"
    Exit Function
  End If    
  
  wmiConnect = True 